Load Sharing & Synchronising Control Modules

DSE8610 MKII

Synchronising & Load Sharing Control Module
The DSE8610 MKII represents the latest in complex load sharing & synchronising control technology. Designed to handle the most complex grid type generator applications the DSE8610 MKII control module is packed with multiple features and benefits that are unrivalled across the generator control industry. 

Calculating Fuel Efficiency and Meeting Green Emission Directives Paper

OVERALL SIZE
245 mm x 184 mm x 51 mm (9.6" x 7.2" x 2.0")

PANEL CUTOUT SIZE
220 mm x 160 mm (8.7" x 6.3")

MAXIMUM PANEL THICKNESS
8.0 mm (0.3")

WEIGHT
0.88kg

PRODUCT VARIANTS
8610-02 - 8610 MKII Synchronising & Load Sharing Control Module (Ct, Rtc)



Request a Quote

e -
Please select a product
Please enter a quantity
e +

add another product

Please enter your title
Please enter your first name
Please enter your surname
Please enter your company name
Please select a country
Please select a delivery location
Please enter your email

Invalid recaptcha
l

Product Highlights

Key Features & Benefits

Key Features

Key Benefits

Extended PLC function types.
Provides ultimate flexibility for complex grid type generator installations.
Redundant MSC.
Allows two MSC links to be connected between multiple DSE86xx MKII control modules.
Type 1 fully flexible inputs.
Flexible for configuration as voltage, current or resistive.
Two RS485 ports.
Aids communication with electronic engines and building management systems.
Three CAN ports.
Ultimate CAN flexibility. Connect to DSENet devices, communicate with electronic engines and maintain a redundant MSC link.
32-set synchronisation.
Offers optimum flexibility for system expansion.
Configurable inputs/outputs (12/8).
Provides multiple installation options.
Dead bus sensing.
Provides rapid power delivery on multi-set systems.
Remote communications (RS232, RS485, Ethernet).
Provides secure and simple off site monitoring. All ports are continuously active.
Direct governor control.
Eliminates the requirement for external control equipment.
kW & kV Ar load sharing.
Provides controlled power delivery.
Configurable event log (250).
Provides access to historical alarms and operational status.
Load switching, load shedding & dummy load outputs.
Allows load options and dummy load requirements to be independently controlled.
Power monitoring (kW h, kVAr, kv Ah, kV Ar h), reverse power protection, kW overload protection.
Provides clear accurate power measurement information.
Data logging (USB Memory Stick).
Provides current and historical status information.
DSE Configuration Suite PC Software.
Provides complete user-friendly configuration and easy-to-use high-level system control & monitoring.
Tier 4 CAN engine support.
Ensures the control module can be used with the latest in modern electronic engine technology.
  • Additional Features
  • Large internal memory.
  • Large heated display.
  • One piece module fascia.
  • Neutral voltage displacement.
  •  
  • Frequency & voltage control.
  • Enhanced measurement accuracy.
  • R.O.C.O.F & vector shift.
  •  
  • Electrical protections.
  • Audible alarms.
  • Configurable timers & alarms.
  •  
  • Generator load demand.
  • Modbus RTU/TCP support.
  • Configurable maintenance alarms (3).
  •  
  • Automatic hours run balancing.
  • Configurable display languages.
  • Flexible sender inputs.
  •  
  • Multiple date & time scheduler.
  • Bus failure detection.
  • CANbus for electronic engines.
  •  
  • SMS messaging start & stop functionality.
  • Comprehensive fuel monitoring.
  • Modem diagnostic tool.
  •  
  • Backed-up real time clock.

Specification

DC SUPPLY

CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous

CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries

MAXIMUM OPERATING CURRENT
460 mA at 12 V, 245 mA at 24 V

MAXIMUM STANDBY CURRENT
375 mA at 12 V, 200 mA at 24 V

CHARGE FAIL/EXCITATION RANGE
0 V to 35 V

OUTPUTS

OUTPUT A (FUEL)
15 A DC at supply voltage

OUTPUT B (START)
15 A DC at supply voltage

OUTPUTS C & D
8 A AC at 250 V AC (Volt free)

AUXILIARY OUTPUTS E,F,G,H,I & J
2 A DC at supply voltage

GENERATOR & BUS

VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
25 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

MAGNETIC PICK-UP
VOLTAGE RANGE
+/- 0.5 V to 70 V

FREQUENCY RANGE
10,000 Hz (max)

BUILT-IN GOVERNOR CONTROL

MINIMUM LOAD IMPEDANCE
1000Ω
Fully isolated

GAIN VOLTAGE
0 V to 10 V DC
Fully isolated

OFFSET VOLTAGE
+/- 10 V DC
Fully isolated

BUILT-IN AVR CONTROL

MINIMUM LOAD IMPEDANCE
1000Ω
Fully isolated

GAIN VOLTAGE
0 V to 10 V DC
Fully isolated

OFFSET VOLTAGE
+/- 10 V DC
Fully isolated

Environmental Testing Standards

ELECTRO-MAGNETIC  COMPATIBILITY
BS EN 61000-6-2
EMC Generic Immunity Standard for the Industrial Environment.
BS EN 61000-6-4
EMC Generic Emission Standard for the Industrial Environment.

ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment, including Electrical Business Equipment.

TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30°C.
BS EN 60068-2-2
Bb/Be Dry Heat +70°C.

VIBRATION
BS EN 60068-2-6
Ten sweeps in each of three major axes.
5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn.

HUMIDITY
BS EN 60068-2-30
Db Damp Heat Cyclic 20/55° C @ 95% RH 48 Hours.
BS EN 60068-2-78
Cab Damp Heat Static 40° C @ 93% RH 48 Hours.

SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes 15 gn in 11 ms.

DEGREES OF PROTECTION PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the control panel with the optional sealing gasket.

Connection Diagram

DSE8610 MKII connection diagram

Product Variants